Kitchen 

Iron: At first, the water is clear, but when in contact with air, stained brown and form deposits on sanitary facilities. Metallic taste. Norm 0.2 mg / l. 

Manganese: At first, the water is clear, but when in contact with air, there is a dark shade and form a black precipitate on the sanitary facilities. Metallic taste. Often manganese is supplied with iron. The provision 0.05 mg / l. 

Limescale: Hardness salts, Ca and Mg form limescale deposits on sanitary facilities. Limescale is a result of clogged pipes, shower strainers, heaters fouling. Technical equipment rapidly wears out or increases power consumption. 

Smell: Just out of the tap to pour cold water felt a specific smell. It can be as foul eggs or swamp. 

Bacteria, viruses: Bacteria, viruses, and other pathogens are extremely dangerous to human health but can not be determined visually by looking at water, as they are relatively small. To be absolutely sure of bacteriologically clean water should bacteriological water analysis. The bacteriological water pollution is more common in virzsemes water (rivers, lakes, ponds, open wells) and the centralized water supply networks. 

Turbidity: Most often found in drinking water network, especially in times when water pipes are made repair or disconnecting, cleaning and so on. Clear water might contain floating particles that are visible. Turbidity in water is as unexpected, uninvited guest who may appear in the worst possible moments. If the filter will not be installed, all washes clothes could became dirty. As another example, it is unpleasant to take a shower in dirty, muddy water with bad odour. 

Organic: It creates a yellowish-brown water and brown precipitate in comparison with iron deposits can be easily removed. Such water is high bacteriologically unsafe. 

Increased salt content: it is possible for groundwater, like the seas and oceans. Groundwater total salt content is relatively much smaller than the seas or oceans, but a problem - a precipitate of sanitary facilities, salty taste of the water, etc. 

Ammonium: Ammonium ions in potable water may adversely affect the effectiveness of the disinfection of water by impairing the manganese may cause damage to the filter (in water systems containing more nitrate) as well as adversely affect water taste and smell. There is a definite threshold odor of ammonia concentration - 1.5 mg / l (at an alkaline pH), but the taste changes can be detected if the ammonium concentration is 35 mg / l, more particularly, a susceptible individual may feel ammonium ions, even if concentration level lower.

Available at stock

Description

 WATEX RO75GPD drinking water filter is filtration system with 5 stages of purification, including mechanical, activated carbon and reverse osmosis. Water is purified from rust, scale, chlorinated organic and organic pollution, heavy metal compounds, nitrites, nitrates, ammonia, pesticides, and etc. harmful impurities. The water has improved taste and liquidated odour. Water is purified from the bacteriological contamination too – microorganisms, bacteria and viruses. Water after filtration has a low degree of mineralization.

 

 

Drinking water in the filter is not applied to any chemical reagents, only various degrees of filtration and activated carbon adsorption. The water after the filtration is healthy for the human body and houseplants. Household appliances last longer - iron, coffee machine, kettle, etc.

 

  • Easy maintenance – easy replaceable elements, quick connection technology
  •  High quality and strength of body, connections and filter elements
  • Easy to install in kitchen cabinet under the sink
  • Long-term investment - ten years or more
  • Low operating costs - variable elements serve for long time

 

Reverse osmosis water treatment method is widely used in disaster situations (floods, earthquakes, etc.), military missions, regions with high population density and pollution level, as well as for sea and ocean water desalination. It provides a guaranteed 99% clean water for health and drinking, without the prior heat treatment.

 

   

WATEX RO75GPD

WATEX RO75GPD+

Completion

Without pump

With booster pump

Flow rate*

7 litres/hour

11.7 litres/hour

168 litres/day

280 litres/day

Incoming water pressure

2.4 – 4 bar

1 – 4 bar

Incoming water

From the central water supply system or underground water without iron

From the central water supply system or underground water without iron

Necessary connections

Water supply, sewerage

Water supply, sewerage and electricity 220V

Size of installation (length x width x height)

420 x 160 x 460 mm

422 x 200 x 467 mm

Size of purified water tank

diameter 240 mm x height 350 mm

Filter weight (empty)

8.5 kg

Volume of purified water in the tank

~5 litres

~5 litres

Electricity consumption

0

24 W

The ratio of membrane rinsing water – clean: rinsing**

1:3

1:3

* Equipment flow rate depends on the incoming water pressure, temperature and salt concentration.

** Rinse volume to sewage decreases at higher input pressure.

 

Equipment is equipped with an automatic shut-off valve which concludes the leakage to sewage water after filling up the water tank. This allows to use water resources economically. Due to manual flushing function of reverse osmosis membrane it will prolong the service of filter comparing to traditional systems.

 

5-STAGE WATER TREATMENT

1. The polypropylene cartridge (5μm) - performs protecting function of the reverse osmosis membrane from mechanical particles (sand, scale, rust and sediment).

2. Carbon cartridge - for protection of reverse osmosis membrane from the removal of free chlorine and organic compounds, flavours, smells, colours.

3. Polypropylene Cartridge (1 µm) – for protection of osmosis membrane from activated carbon dust and to prolong its life service.

4. The reverse osmosis membrane (pore diameter 0,0001μm) - the basic element of water purification. Cleans drinking water from scale, bacteria, viruses, organic matter, colloids, pesticides, radioactive particles, microbes, algae, heavy metals and dissolved minerals.

5. Carbon post-filter - designed to improve the organoleptic characteristics issued on water consumption.

 

SET INCLUDES

·      Filter for purification of drinking water

·      The tank for purified water (8 litres)

·      Tap for drinking water

·      Key for the installation of the filter

·      Materials for the installation

·      Instructions for installation and use

 

how often exchange elements

1-3: degree of purification (meh. filter 5 µm + carbon + meh. filter 1 µm) once in 6 -12 months.

4: reverse osmosis membrane once in 2 years or after flow reduction

5: carbon post-filter element once a year.

Element replacement frequency depends on the water consumption and incoming water quality.

The quality of all equipment components and their testing methods, fully compliant with the NSF (National Science Foundation) requirements to ensure high effectiveness in the long term.